This product is no longer promoted on Made-in-China.com. If you find any infringement or
sensitive information of it, please contact
us for
handling. Thank you.
Product Feature 1. Large-screen LCD display, real-time display of various temperature and operating conditions, clear and intuitive content, and truly realize the man-machine dialogue.
2. Power-on self-test, wide-range self-diagnosis function, can accurately determine the fault location and alarm.
3. Six-channel independent temperature control (the vaporization chamber and capillary vaporization chamber can independently control the temperature), eight-step temperature program function.
4. Over-temperature protection function: if any channel exceeds the set temperature, the instrument will automatically power off and alarm.
5. The unique vertical heating device makes the sample vaporization more reliable, minimizes the heat radiation generated by the vaporization chamber, and ensures that the temperature deviation in the oven is extremely small.
6. The door opening system after the intelligent fuzzy control automatically tracks the temperature and dynamically adjusts the angle of the air door to truly achieve near room temperature operation.
7. Equipped with packed column stigma injection, glass lining injection, capillary split/splitless injection device with diaphragm cleaning function, and a gas sampler can be installed.
8. High-precision dual-stable gas circuit, three kinds of detectors can be installed at the same time. Technical Parameter
Model
OKGC-8960B
Relative Humidity
< 85%
Power
2000W
Measuring Range
customizable
Measuring Object
customizable
Net Weight
40kg
Size
550*535*485mm
Oven Size
240*250*155mm
Column Installation Interval Size
152.4mm(6 inch standard interface)
Oven Temperature Control
Room temperature plus 8ºC~400ºC, (optionally set in 1ºC increments)
≤5 x 10-13 A/30 min (after the instrument is stable for 1 hour)
Linear Dynamic Range
≥107
Insulation Strength
≥1500 volts, 220V leakage current ≤ 1mA
2.Thermal Conductivity Detector (TCD)
Sensitivity
S≥8000mv.ml/mg (n-hexadecane)
Baseline Noise
≤20uv
Baseline Drift
≤100uv/30min (after the instrument is stable for 1 hour)
Linear Dynamic Range
≥104
Application & Solutions
Gas analysis of pressure transformer oil (GB/T 17623-1998, DL/T 722-2000, DL/T 703-1999)
Air quality (TVOC, benzene, total hydrocarbon and non-methane total hydrocarbon) analysis (GB/T 50325-2001, GB/T 18883-2002, gb16927-1996); Workshop exhaust gas, flue gas analysis, and VOC, benzene and non-methane total hydrocarbon in flue gas 24 hours uninterrupted online analysis;
Natural gas, refinery gas, pyrolysis gas, artificial gas and other industrial gas gas analysis (simple single valve type, wide spectrum process double valve four-column economy type, wide spectrum process three valve four column practical type, wide spectrum process five valve six column high end type, three valve four column TCD type, four valve five column double TCD type, etc. In accordance with GB/T 13610-2003, UOP539, ASTM1945, ASTM D 1946 and GPA2261; Can be customized according to the user's specific samples);
Safety gas analysis in underground coal mine gas chromatography (available for 24 hours continuous cycle sampling analysis of 32 points);
Water quality analysis (accord with GB/T 5750-2006);
Gas, methane analysis (H2, O2, N2, CH4, CO, CO2 six components, unique single valve sequence conversion);
Sulfur compounds in natural gas (unique single-valve sequence reversal method for detection of H2S, CSO, SO2 and total sulfur);
High purity gas analysis, electronic industrial gas analysis (minimum detectable concentration up to 10ppb);
Benzene and toluene in gasoline (accord with ASTM D3606; SH/T 0713-2002);
Analysis of oxygen-containing compounds in gasoline (accord with ASTM D4815 and SH/T 0633-1998);
Analysis of benzene, toluene and aromatics in gasoline (in accordance with ASTM d5580-1995, SH/ t0693-2000);
SOA analysis of hydrocarbon group composition in gasoline (content detection of saturated hydrocarbon, olefin, aromatic hydrocarbon and benzene, using a special olefin adsorption trap; In line with SH/T 0741-2004), PONA analysis of single hydrocarbon in gasoline and CPNA analysis of the composition of carbon family;
Simulated distillation gas chromatography (accord with SH/T 0558, ASTM D5307, D3710, D6352, D2887);
Blood ethanol analysis (in line with the ministry of public security standard GA/ t105-1995);
Cigarette sticks VOC (in line with YC/T 207-2006), drug residue analysis, ethylene oxide in medical devices (in line with GB/T 16886.7-2001), solvent residue detection in packaging materials;
Gas chromatography for room temperature gases (CO2, CH4 and N2O, 0.1ppm-100%);
Catalytic evaluation, Fischer-Tropsch synthesis, high pressure and high temperature on-line analytical system (system chromatography based on requirements);
Process gas chromatography (industrial chromatography), sample pretreatment, analysis cabin construction, multiple flow path sample selection. (up to 32 sample options are supported), etc